Diathermy 400 Plus


Features :

  • Minimum cutting effect
  • Spray coagulation
  • Automatically stops energy
    delivery as soon as the seal
    cycle is complete
  • Feedback-controlled response system
  • Provides good hemostasis effect

Cut :

  • Pure cut - It produces a high-frequency alternating current for smooth, rapid cuts with little or no hemostasis
  • Blend 1 - This mode offers varying degrees of hemostasis to surgeon in cut mode
  • Blend 2 - The mode helps in vaporization of prostatic tissue or any fat tissue. The high wattage output offers fast cutting of tissues
  • Endo cut - The automatic cut system is used for the reduction in complication rate of endoscopic sphincterotomy (EST) and serum hyperamylasemia after EST in comparison with the conventional blended cut mode.

Coag :

  • Force : The Force mode covers the demands of standard coagulation by producing fine waveform that creates superficial resistance in the tissue resulting in superior coagulation, where the tissue destroyed by hyper evaporation. This enable surgeons for the removal of surface structures without damaging deep or peripheral tissues and to cauterize large surface areas quickly when required.
  • Spray : The mode supports direct coagulation at tissue with spark. The CREST FACTOR is high thus not giving any cutting effect to the tissue.
  • Fulgurate : It raises the voltage to produce a spark between electrodes for the coagulation of tissue. There is no contact between tissue and electrode.
  • Desiccate : This Coagulation in which electrode is in direct contact with the tissue is referred to as desiccation and is the type of coagulation used in most surgeries. It ensures pinpoint desiccation with less destruction of peripheral tissue
  • Bipolar feature : Coagulation without charring, adhesion and blanching of adjacent tissues

Bipolar :

  • Micro : High Voltage force coagulation for special purpose when speed is required.
  • Macro : For highly precise control over coagulation process and privations of carbonization.
  • Cut : This Bipolar CUT technology nearly eliminate excessive current, even during precision cutting in minute SAFETY FEATURES tissue structure.
  • Auto : Coagulation start by pressing the footswitch and stops output and audio signal automatically when the tissue is coagulated.

Specifications :

  • Program mode : 99 User settable program mode
  • Frequency : 480khz
  • Display : 7segment LED
  • Weight : 7.5Kg (approx)
  • Dimension : 410mm(L) x 355mm(W) x 155mm(H)
  • Voltage : Input Supply Voltage 230V (+ / - 15%) 50Hz

Applications :

  • Microsurgery
  • Laproscopy
  • Gynecology
  • Urology
  • Neurology
  • Thorasic
  • Plastic & reconstructive surgery
Technical Specifications:
Cut :

MODEMAX POWERLOADCREST FACTOR
Pure400 W300 E1.5
Blend 1250 W300 E1.5
Blend 2200 W300 E1.5
Endocut99 %300 E1.5
Coag :

MODEMAX POWERLOADCREST FACTOR
Spray120 W300 E7
Force120 W300 E6.5
Fulgurate150 W300 E6
Dessicate150 W300 E6
Bipolar :

MODEMAX POWERLOADCREST FACTOR
Micro80 W100 E1.5
Macro80 W100 E1.5
Cut100 W100 E1.5
Auto150 W100 E1.5
st

Categories

Quick Contact